TURBO FIRE (HOT WATER)
The Turbo Fire Hot Water Boilers provide for exceptionally high efficiencies, lower fuel costs, and extremely rugged construction.

OTHER FEATURES :
  • Compact space saving vertical design
  • Four-Pass Design
  • Shock Proof, no tubes to loosen or burn out
  • Convenient access to “eye high” burner
  • Solid State controls for trouble free operation
  • Factory assembled, fully automatic
  • UL and ASME CSD - 1
  • Simple and inexpensive to install
  • Low water pressure drops
  • Standard design pressure of 30 PSI
    Optional to 160 PSI, 250° F
Turbo Fire Specifications
- BOILER HORSEPOWER - 6 10 15 20 25 30 40 50 60 70 80 100 -
- GROSS OUTPUT (MBH), BTU X 1000 201 335 502 670 837 1004 1339 1674 2009 2343 2678 3348 -
- KCAL X 1000 51 84 127 169 211 253 337 422 506 590 675 844 -
- INPUTREQUIRED BTU X 1000 251 418 628 837 1046 1255 1674 2092 2511 2929 3348 4184 -
- KCAL X 1000 63.3 105 158 211 264 316 422 527 633 738 844 1054 -
- FIRING RATENAT. GAS 1000 BTU/FT3 FT 3/HR. 251 418 628 837 1046 1255 1674 2092 2511 2929 3348 4184 -
- M 3/HR. 7.1 11.8 17.8 23.7 29.6 35.5 47.4 59.2 71.1 82.9 94.8 118.5 -
- FIRING RATELP. GAS 91,500 BTU/GAL. GPH 2.7 4.6 6.9 9.1 11.4 13.7 18.3 22.9 27.4 32 36.6 45.7 -
- LPH 10.4 17.3 26 34.6 43.3 51.9 69.2 86.6 103.9 121.2 138.5 173.1 -
- FIRING RATE#2 OIL 140.000 BTU/GAL. GPH 1.8 3 4.5 6 7.5 9 12 14.9 17.9 20.9 23.9 29.9 --
- LPH 6.8 11.3 17 22.6 28.3 33.9 45.3 56.6 67.9 79.2 90.5 113.1 -
A OUTLET SIZE IN. 2 2 2 3 3 4 4 6 6 6 6 6 A
MM 51 51 51 76 76 102 102 152 152 152 152 152
B RETURN SIZE IN. 2 2 2 2.5 2.5 3 3 4 4 4 4 4 B
MM 51 51 51 64 64 76 76 102 102 102 102 102
C DRAIN SIZE IN. 1 1 1 1 1 1.25 1.25 1.25 1.25 1.5 1.5 1.5 C
MM 25 25 25 25 25 32 32 32 32 38 38 38
D STACK DIA. IN. 8 8 8 8 8 10 12 12 12 14 14 14 D
MM 203 203 203 203 203 254 305 305 305 356 356 356
E STACK HEIGHT IN. 52 52 58 64 64 63 73 83 83 82 82 82 E
MM 1321 1321 1473 1626 1626 1600 1854 2108 2108 2083 2083 2083
F WIDTH WITHOUT TRIM IN. 35.2 35.2 35.2 35.2 35.2 41 50 59 59 68 68 78.2 F
MM 894 894 894 894 894 1041 1270 1499 1499 1727 1727 1986
G WIDTH WITH TRIM IN. 42 42 42 42 42 47 55 63 63 72 72 82 G
MM 1067 1067 1067 1067 1067 1194 1397 1600 1600 1829 1829 2083
H OVERALL HEIGHT IN. 70 70 76 82 82 82 93 105 105 106 106 106 H
MM 1778 1778 1930 2083 2083 2083 2362 2667 2667 2692 2692 2692
I HEIGHT WITHOUT TRIM IN. 65 65 71 77 77 77 88 98 98 98 98 98 I
MM 1651 1651 1803 1956 1956 1956 2235 2489 2489 2489 2489 2489
J LENGTH IN. 60 60 60 60 60 78 87 115 115 120 120 127 J
MM 1524 1524 1524 1524 1524 1981 2210 2921 2921 3048 3048 3226
- WATER CAPACITY GALS. 62 62 68 79 79 113 208 313 313 440 440 591 -
- LITERS 235 235 257 299 299 428 787 1185 1185 1665 1665 2237 -
- SHIPPING WEIGHT LBS. 1600 1600 1750 1800 1800 2175 3775 5300 5300 7300 7300 8700 -
- KG. 726 726 794 816 816 987 1712 2404 2404 3311 3311 3946 -
- BOILER HORSEPOWER - 6 10 15 20 25 30 40 50 60 70 80 100 -
Outlet connection over four inches are 150# flanges. All other connections are NPT. We assume no responsibility for errors in data.