SCOTCH
BOILERS
Complete
State of the Art Boiler Systems
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CRG BOILER SYSTEMS provides
a full line 2 & 3 Pass Dry Back Scotch Marine Boilers and
3&4 Pass Wet Back Scotch Marine Boilers. CRG Boilers are suited
for any industries needs commercial, industrial, agricultural.
For food processing and food service companies CRG's boilers can
be modified with a stainless steel jacket to meet sanitation requirements.
For more information and specifications see below or go to our
contacts page.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Quality Assurance & Durability
Each boiler is inspected a by Hartford Inspector
who is commissioned by the National Board of Boiler and Pressure
Vessel Inspectors, assuring that the quality and durability of
the ASME Code is followed in construction of each unit.
Design
The use of computer aided design techniques allows
for more accurate calculations of construction material and highest
utilization of the boiler's performance.
Compact
The computer-aided design has made this unit a space saving workhorse
without sacrificing the principle of 5 sq. ft. per BHP
Combustion
CRG uses only the best in name brand burners, primarily
GORDON-PIATT & POWER-FLAME. (Others available upon request)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(3)
Pass Wet Back click link for specs
Our (3) pass wet-back eliminates the well known
problem of failing refractory baffles between gas passes, this
eliminates hot gasses short circuiting directly into the stack,
costing thousands annually.
Tube sheets
This (3) pass wetback design has independent
tube sheets resulting in uniform temperatures across sheets. This
eliminates large temperature variations resulting in pre-mature
tube and or tube-sheet failure.
Maintenance & Access
With no refractory baffles to replace or maintain
means this is a cost saving workhorse with easy access, no heavy
refractory rear door to contend with, or no burner gas train or
linkage to remove, one man can easily open and close this unit
for annual inspection.
Efficiency
Each unit is designed for optimum fuel efficiency
and has proven in certified test to meet and often exceed the
efficiencies of 4-pass dry-back boilers.
|
|
|
|
CRG 3 Pass Wetback
Scotch Marine Boiler with its space saving design and fuel
efficiencies makes it the perfect choice for agricultural
industry. The 3 pass boiler comes in two version steam or
hot water and is suitable for stationary or mobile applications.
(This 400bhp 3 pass Wetback Boiler was installed in a feedmill
in Colorado.) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(4)
Pass Wet Back click
link for specs
This unit has independent rear tube sheets
resulting in an even temperature across each sheet, allowing
tubes and tube-sheets to move together as each is seeing
the same temperature in each pass, this also helps to prevent
pre-mature tube and tube sheet failures due to uneven temperatures
on a single tube sheet.
The only refractory in the rear of this
boiler is a 18 access plug to be removed to inspect
the furnace, this results in no burner parts having to be
removed or heavy back door to be opened, one man can open
and close for annual inspection.
This is a low maintenance unit with no refractory
rear doors of baffles to crack, fall-out resulting in short
circuiting gases direct to the stack.
CRG has only top name brand burners, firing
Natural Gas, # 2 Thru # 6 Oil, LP Gas and Digester Gas GORDON-PIATT
& POWER-FLAME.(others available upon request)
This (4) pass unit has been designed for
Highest Fuel Efficiency. The fourth pass has been designed
to remove every BTU possible that would otherwise be vented
through the stack in similar designed boilers. This unit
has proven to be as efficient and in some cases far greater
than other units of similar design
|
|
|
|
All
those timely and costly problems have been designed out of
this 4-pass unit. It has a full wet-back radiant heat transfer
area that promotes superior internal water circulation and
rapid heat absorption. This results in thousands of dollars
savings annually, not one year, not two years, but annually
as long as the unit is in service.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
COMPLIANCE: All (2) & (3) pass dry-back
boilers are built in Accordance with the ASME CODE, and Inspected
by an Assigned Inspector Commissioned by the National Board of Pressure
Vessel Inspectors, then assigned a National Board Number. This assures
that each boiler is built with the quality of the ASME Code &
National Board of Pressure Vessel Designs.
Construction: Each
combustion chamber is designed with Computer aided calculations
to be large enough to allow low heat release for complete combustion.
Large 12 X 16 manholes are standard on larger units (70 HP &
UP). Hand holes for cleanout are 3" x 4". Front doors
are hinged, bolted and insulated to provide easy access to fire-tubes.
Rear doors are hinged and davited with 16" diameter access
door with 2" observation port, (80 HP & larger). Stack
connection is slip-on (2 Pass in Front) (3 Pass in Rear) Each
boiler shell is insulated with hi-density fiberglass, and then
covered with 22 ga. Grip jacketing coated with International Red,
Industrial grade epoxy enamel. Tubes are 2.5" 12 Gauge, 178A
Flare Rolled & Beaded on all Power Boilers. Heavy-duty saddle
with support legs mounted to heavy-duty steel skid provides support
for boiler and burner. Two lifting lugs are securely welded to
top of the shell for ease of off-loading and moving boiler into
position for final connections.
Standard Steam Trim
· Operating & Limit Pressure Controls
· Modulating Pressure Control on Modulating Burners
· Water Column W/ Gauge Glass, MM # 157 Combination Low
Water Cut-Off & Pump Controller
· Probe Aux, L.W.C.O.
· Steam Pressure Gauge With Syphon & Test Cock
· Stack Thermometer
· Water Column Drain Valve
· Safety Relief Valve(s) Per ASME Code
Standard Water Trim
· Operating & Limit Temperature Control
· Modulating Control of Boilers W/ Modulating Burners
· Probe Type Low Water Cut-Off Control
· Combination Pressure, Temperature, Altitude Gauge
· Stack Thermometer
· Hot Water Return Baffle for Thermal Shock Resistance
· Safety Relief Valve(s) Per ASME Code
Burners
CRG uses only name brand burners
· POWER-FLAME
· GORDON-PIATT
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C.R.G.
Electric, Inc /CRG Boiler Systems
PO Box 69008
Odessa, Tx 79769
Ph. (432) 381-2493
Fax. (432) 381-2724
Email
us
|
|
CRG
Boiler Systems
3939 E. Hwy. 80 Ste, 104G
Mesquite, Tx. 75150
Ph. (972) 698-6382
Fax. (972) 698-7288
Email
us
|
|
|
|
More Contact info click here
|
|
Copyright © CRG Boiler Systems
a Div. of C.R.G. Electric, Inc 2002
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|